Lab Safety
This page shows how we kept our work with genetically modified bacteria and hazardous chemicals, including testosterone, safe: training and rules, equipment, waste handling and risk assessments. All strains, constructs, chemicals and samples were handled according to approved laboratory procedures and disposed of according to Lund University's waste-management requirements. The safety of the bacterium itself (in-host control, environmental biocontainment and GMO regulations) is on the Biosafety page.
Safety in the Lab
All members performing experiments in the laboratory received the required safety training from our PIPrincipal investigator: the senior researcher who leads the lab group. (Johan Svensson Bonde), and completing it was mandatory before the team started work in the laboratory. It was also made mandatory to read General Safety Regulations, Lund University's own safety handbook (Kemicentrum, n.d.), which has information on how to perform safe lab work at Kemicentrum, the chemistry building on the university's campus.
When performing experiments inside the lab, the team always wore appropriate clothing such as lab coats, gloves, safety goggles and closed shoes, and consumption of food and drinks was strictly prohibited inside the laboratory areas. The team ensured that the workbench was always cleaned with 70% v/vv/v means volume per volume: 70 mL of ethanol in every 100 mL of liquid. ethanol at the end of the lab day and made sure that the equipment used was properly cleaned and switched off when not in use.
To ensure the safety of the team members and to provide guidance, at least one instructor was present throughout the lab work and no lab work was carried out alone. All hazardous wastes were disposed of according to Lund University's regulations (Kemicentrum, Lund University, 2025), which are in line with EU and Swedish regulations. The team also ensured that all safety rules were enforced consistently.
Our laboratory is equipped with:
- Emergency Equipment: Eyewash stations, emergency showers, fire extinguishers, fire blankets and first aid kits.
- Containment Equipment: Biosafety Level 1The lowest containment level, for work with organisms that are not known to cause disease in healthy adults. laboratory with sterile workspaceA clean area where work is done without letting unwanted microbes get in, for example near a flame or in a sterile bench. to perform biological work and chemical fume hoodsA ventilated cabinet that draws harmful fumes away from the user. for preparing and handling hazardous reagents.
- Spill Control: Biological and chemical spill kits, absorbent pads.
- Protective Equipment: Lab coats, nitrile glovesDisposable gloves made of synthetic rubber that resist many chemicals., safety goggles, face shields (when required).
Waste Management
All the biological and chemical wastes resulting from our experiments are properly labeled, segregatedKept apart by type, so that incompatible wastes are never mixed. and disposed of by following Lund University's waste management guidelines (Kemicentrum, Lund University, 2025):
- Biological wastes are autoclavedSterilized with pressurized steam. at 121 °C and 1.1 bar for 30 minutes before they are disposed of along with the general wastes to ensure that no microbial contamination is possible.
- Chemical wastes are segregated in dedicated chemical waste containers found inside the chemical waste cabinets and are disposed of by the university using certified hazardous waste contractors.
- Glass waste, which is not contaminated with any harmful chemicals or biological sources, is collected in dedicated bins before being disposed of along with regular glass waste.
- Sharp objects are disposed of immediately after they are carefully collected and labeled in puncture-proof containers and the containers are checked regularly to ensure that they are never overfilled.
Hazard Identification and Risk Assessments
Biological Risks
The team works only with the bacterial strains Escherichia coli BL21(DE3) and Escherichia coli TG1, which are considered low risk as they belong to Risk Group 1The lowest risk class: organisms unlikely to cause human or animal disease.. We still made a risk assessment for every experiment before it was performed, and all recombinant DNA workWork in which DNA from different sources is combined, for example inserting a gene into a plasmid. followed Lund University's guidelines (Kemicentrum, n.d.) and EU Directive 2009/41/ECThe EU rules for working with genetically modified microorganisms in closed laboratories and facilities. on the contained use of genetically modified microorganisms (Directive 2009/41/EC).
Chemical Risks
The team also works with toxic chemicals such as beta-mercaptoethanolA reducing agent used in protein sample buffers. It is toxic and has a strong smell., methanol, imidazoleA chemical used to wash proteins off a His-tag purification column. and nickel(II) sulfateA nickel salt used to charge His-tag purification columns., which are known to be reproductive toxicantsChemicals that can harm fertility or an unborn child., and their handling is restricted accordingly. Testosterone also presents dermal and mucosal exposureContact with the skin or with moist body linings such as the eyes and mouth. risks from spills or from handling the solid, and is accessed only by dedicated personnel. All chemicals were handled in designated areas, with reference to the Material Safety Data Sheets (MSDS)Documents that describe a chemical's hazards and how to handle it safely..
The risk assessments for our lab procedures were made before we started working in the laboratory and are linked below, together with the testosterone safety data sheet and handling assessment.
- Risk Assessment document for Autoclaving Procedure
- Risk Assessment document for Bunsen Burner
- Risk Assessment document for cloning
- Risk Assessment document for colony PCR
- Risk Assessment document for competent cell preparation
- Risk Assessment document for gel electrophoresis
- Risk Assessment document for His-tag purification
- Risk Assessment document for media preparation and cultivation
- Risk Assessment document for PCR clean-up and gel filtration
- Risk Assessment document for PCR
- Risk Assessment document for plasmid digestion
- Risk Assessment document for plasmid mini-prep
- Risk Assessment document for protein production
- Risk Assessment document for SDS-PAGE
- Risk Assessment document for transformation
- Testosterone safety data sheet (MSDS)
- Risk Assessment for testosterone handling
References
- European Parliament and Council of the European Union. (2009). Directive 2009/41/EC on the contained use of genetically modified micro-organisms. Official Journal of the European Union, L 125, 75–97. https://eur-lex.europa.eu/LexUriServ/LexUriServ.do?uri=OJ:L:2009:125:0075:0097:EN:PDF
- Kemicentrum, Lund University. (2025). General safety regulations: 8. Waste handling. Retrieved October 18, 2026, from https://www.kc.lu.se/en/employee/general-safety-regulations/8-waste-handling
- Kemicentrum. (n.d.). General safety regulations. Lund University. Retrieved October 11, 2026, from https://www.kc.lu.se/en/employee/general-safety-regulations